Hallway Bathroom 

Install Anti-Slip Strips 

  • Provide and install safety anti-slip strips rated for wet environments at the following locations: 
  • Bathtub/shower floor 
  • Bathroom floor at bathtub entrance 
  • Bathroom floor at sink 
  • Bathroom floor at toilet 
  • Ensure strips are evenly spaced and securely adhered to flooring surfaces to prevent lifting or peeling. 
  • Product/example: Link 

Replace Showerhead 

  • Remove the existing showerhead and provide and install a dual showerhead system with a handheld showerhead and sliding bar.  
  • Product/example: Link (chrome) 

Replace Shower Faucet Fixture with Matching Set 

  • Remove the existing knob-style shower faucet control and faucet fixture. 
  • Provide and install a matching chrome shower faucet set with a pull/dial-style control for easier operation. 
  • Ensure the new set is compatible with the existing plumbing and verify proper operation following installation. 
  • Color to be chrome  

Install Shower Grab Bar 

  • Provide and install one 24-inch grab bar in a chrome finish on the wall nearest the shower controls. 
  • Mount the grab bar at approximately 33 inches above the finished floor. 
  • Securely anchor the grab bar to appropriate structural supports. 

 

Install Dual Grab Bar with Towel Holder 

  • Provide and install one 24-inch dual grab bar with integrated towel holder on the wall to the left of the toilet. 
  • Mount the grab bar at approximately 33 inches above finished floor. 
  • Product/example: Link (chrome) 

Raise Existing Bathroom Vanity 

  • Evaluate the existing bathroom vanity to determine the feasibility of raising the sink height by approximately 6 inches, from 35 inches to 41 inches above finished floor. 
  • Modify or elevate the existing vanity as necessary to achieve the recommended height while maintaining stability and proper plumbing connections. 
  • Ensure all modifications are securely installed and finished to match the existing vanity as closely as possible. 

Replace Shower Curtain Rod and Curtains 

  • Remove the existing shower curtain rod and curtains. 
  • Provide and install a curved dual shower curtain rod. 
  • Provide and install a new shower curtain and liner. 
  • Securely mount the rod and ensure proper operation. 
  • Products/examples: 

Modify Bathtub for Easier Access 

  • Provide and install a bathtub cut-out conversion to create a lower step-through entry into the existing curved bathtub. 
  • Maintain a step-over height of approximately 6 inches, if feasible. 
  • Use a bathtub modification system compatible with the existing tub’s curved design and construction. Curved bathtub cut-out conversion kits are available. 
  • Contractor to assess the feasibility of the proposed modification prior to bidding. If a bathtub cut-out is not feasible, provide a brief explanation of the limitations or conditions preventing installation. 
  • Finish and seal all modified surfaces to ensure a watertight installation. 
  • Ensure the modified entry provides a smooth, safe transition into the bathing area. 

Install Bathroom Exhaust Fan with Integrated Lighting 

  • Remove the existing bathroom exhaust fan. 
  • Provide and install a replacement exhaust fan with integrated lighting. 
  • Connect to existing electrical and ventilation systems as appropriate. 
  • Verify proper operation of both the ventilation fan and light. 

 

Kitchen 

Install Combination Smoke and Carbon Monoxide Detector 

  • Provide and install one combination smoke and carbon monoxide detector on the kitchen ceiling in an appropriate location. 
  • Install according to manufacturer instructions and applicable safety requirements. 
  • Test following installation to confirm proper operation. 

Install Fire Extinguisher 

  • Provide and install one residential fire extinguisher in the kitchen. 
  • Mount in a readily accessible location as directed by the participant. 
  • Secure using the manufacturer’s mounting bracket. 

 

Front Entryway 

Install House Numbers 

  • Provide and install 8” house numbers displaying house numbers at the front of the home near the front entrance. 
  • Position numbers for clear visibility from the driveway and approaching emergency responders. 
  • Securely mount using exterior-rated hardware. 

 

Outdoor Space – Front Yard and Mailbox  

Install Reflective Address Numbers on Mailbox 

  • Provide and install 4-inch reflective address numbers displaying house numbers on both sides of the existing mailbox. 
  • Ensure numbers are securely attached and visible from both directions of travel. 

Install Directional Address Signage 

  • Provide and install directional address signage in the front yard displaying house number. 
  • Position signage to improve visibility and assist visitors and emergency responders in locating the residence. 
  • Securely install using exterior-rated materials suitable for ground placement. 

 

Side Entry – Exterior 

Install Exterior Railings with Continuous Graspable Handrails 

  • Provide and install new railings on both sides of the existing exterior steps, extending from the exterior wall of the house to the bottom of the stairway. 
  • Exterior railings to be constructed of white poly-composite material. 
  • Provide and install  continuous graspable handrails along the inside of both railing systems. 
  • Graspable handrails to be approximately 1.25 inches in diameter and follow the angle of the stairway for the full stair run. 
  • Extend the inner graspable handrails approximately 12 inches beyond the bottom step, where feasible, without creating an obstruction or safety hazard. 
  • Securely anchor all railings and handrails to appropriate structural supports. 
  • Position graspable handrails to provide continuous support when ascending and descending the steps. 
  • Use exterior-rated materials and hardware suitable for outdoor exposure. 

Install Anti-Slip Stair Treads 

  • Provide and install contrasting anti-slip strips on each existing exterior step. 
  • Position strips near the leading edge of each tread to improve traction and visibility. 
  • Clean and prepare surfaces before installation to ensure proper adhesion. 
  • Use exterior-rated products suitable for weather exposure. 

 

Basement  

Install Combination Smoke and Carbon Monoxide Detector 

  • Provide and install one combination smoke and carbon monoxide detector in the basement. 
  • Position in an appropriate location according to manufacturer instructions and applicable safety requirements. 
  • Test following installation to confirm proper operation. 

Install Fire Extinguisher 

  • Provide and install one residential fire extinguisher in the basement. 
  • Mount to the wall in a readily accessible location as directed by the participant. 
  • Secure using the manufacturer’s mounting bracket. 

 

Contractors interested in submitting a bid may contact the disAbility Resource Center to obtain the project address and schedule a time to visit the site. Site visits are by appointment only and must be coordinated in advance. Inquiries may be emailed to sdavis@cildrc.org. 

 

General Requirements 

  • Verify field conditions and exact quantities; request written approval for any substitutions.
  • Where specific product links are provided in the Scope of Work, contractors must use the exact products referenced in those links unless a written substitution is approved bydRC prior to purchase.
  • All grab bars/rails must support 350 lb+ when properly anchored; coordinate heights per OT input where available.
  • Protect adjacent finishes; clean up daily; provide 1-year workmanship warranty.
  • Work must comply with local building codes and aging-in-place best practices. For pre-1978 homes, EPA Lead-Safe Renovator certification and practices are required for interior work disturbing more than 2sq ft of painted surface.
  • Section 3 Compliance: This project is subject to the requirements of Section 3 of the Housing and Urban Development Act of 1968. Contractors and subcontractors are encouraged to make every effort to employ low-income persons and qualified Section 3 residents and to contract with Section 3 business concerns when feasible. Documentation of outreach and hiring efforts may be requested. 

 

How to Apply / Submit a Bid 

Due by the Closing Date:
• Completed bid/cost estimate with materials and labor itemized separately
• Proof of current Virginia contractor license
• Certificate of Insurance
• Lead-Safe and other certifications (if applicable)
• Completed W-9 

Submit Bids or Questions to:
Samantha Davis, CAPS
Program Manager – Older Adult Home Modification Program
disAbility Resource Center
409 Progress St., Fredericksburg, VA 22401
540-373-2559 • 📧 sdavis@cildrc.org 

 

Award Information 

All bids will be reviewed for completeness, qualifications, and compliance with HUD requirements. The contract will be awarded to the bidder whose proposal is determined to be most advantageous to the project, considering price, experience, capacity, and overall responsiveness. Contractors may be contacted for clarification before an award decision is made. Award notifications will be posted and emailed within ten (10) business days of the closing date. 

Recommended Posts

No comment yet, add your voice below!


Add a Comment

Your email address will not be published. Required fields are marked *