OAHMP-VAHMR0054-24 / Unit #14711
Posting Date: 10/23/26
Closing Date: 11/17/26
Location / Service Area: Spotsylvania County, Virginia
Brief Project Description / Summary of Work
Front Entry
Evaluate and Repair or Replace Front Door Threshold
- Evaluate the existing front entry threshold, including the large crack and any damaged or deteriorated areas.
- Repair or replace the threshold as necessary to eliminate the trip hazard and provide a smooth, stable, and secure walking surface.
- Coordinate work with the existing front entry door and replacement storm door to ensure proper clearance, sealing, and door operation.
Replace Front Door Hardware
- Remove existing round doorknob from the main front entry door.
- Provide and install lever-style door hardware compatible with the existing door.
- Ensure door opens, closes, latches, and locks properly.
Replace Front Storm Door
- Remove existing front storm door and replace with a new exterior storm door sized appropriately for the existing opening, approximately 36″ x 80″.
- Install all necessary hardware for proper operation.
- Ensure storm door opens, closes, and latches properly.
- Repair and finish areas disturbed by installation as needed.
Ensuite Bathroom
Replace Toilet
- Remove existing toilet and replace with an 18″ comfort-height toilet.
- Install using manufacturer-recommended hardware and connections.
- Ensure toilet is securely installed, level, and fully operational.
Install Anti-Slip Strips
- Provide and install anti-slip strips on the bathroom floor in front of the toilet, shower, sink, bathroom entrance, and shower floor.
- Ensure strips are evenly placed and securely adhered to prevent lifting or peeling.
- Product Link
Install Dual Shower Head with Sliding Bar
- Remove existing shower head and replace with a dual shower head system with handheld shower head and sliding bar.
- Securely mount sliding bar for convenient use by participant.
- Verify proper operation and check connections for leaks.
- Product Link
Improve Bathroom Lighting
- Evaluate the existing vanity light fixtures and overhead ceiling light to determine necessary improvements.
- Replace the existing broken vanity light fixtures with new, brighter fixtures, utilizing existing wiring and fixture locations.
- Replace the existing single-bulb overhead ceiling light fixture with a two-bulb fixture to improve overall bathroom illumination.
- Confirm fixture selections with participant prior to installation.
- Ensure completed work provides adequate illumination throughout the bathroom for safe use and navigation.
Install Tub-Mounted Support
- Provide and securely install a clamp-style tub support on the edge of the existing bathtub.
- Verify compatibility with the existing bathtub prior to installation.
- Install according to manufacturer instructions and confirm support is secure and stable.
- Product Link
Living Room
Install Window Heating and Cooling Unit
- Remove the existing cooling unit and replace it with the specified heating and cooling unit.
- Leave the existing cooling unit with the participant for her to keep or dispose of at her discretion.
- Provide and install a window-mounted heating and air-conditioning inverter unit in the living room.
- Unit to be compatible with the existing approximately 36″ wide window.
- Secure unit according to manufacturer requirements and properly seal around the installation.
- Verify heating and cooling functions are operational upon completion.
- Product Link
Install Smoke/Carbon Monoxide Detector
- Provide and install a combination smoke and carbon monoxide detector in an appropriate location.
- Test following installation to confirm proper operation.
Install Fire Extinguisher
- Provide and securely mount a household fire extinguisher.
- Confirm final mounting location with participant prior to installation.
- Mount in an accessible location that does not obstruct the normal path of travel.
Bedroom
Install Window Heating and Cooling Unit
- Provide and install a window-mounted heating and air-conditioning inverter unit in the bedroom.
- Unit to be compatible with the existing approximately 36″ wide window.
- Secure unit according to manufacturer requirements and properly seal around the installation.
- Verify heating and cooling functions are operational upon completion.
- Product Link
Install Smoke/Carbon Monoxide Detector
- Provide and install a combination smoke and carbon monoxide detector in an appropriate location.
- Test following installation to confirm proper operation.
Install Fire Extinguisher
- Provide and securely mount a household fire extinguisher.
- Confirm final mounting location with participant prior to installation.
- Mount in an accessible location that does not obstruct the normal path of travel.
Back Entryway
Install Exterior Lighting
- Provide and install an exterior floodlight at the eave above the side exterior door leading to the wooden wheelchair ramp.
- Position the fixture to illuminate the side entrance, ramp entrance, and surrounding walking surface.
- Ensure fixture is securely mounted and fully operational upon completion.
- Product Example
Install Anti-Slip Strips on Wooden Ramp
- Provide and install exterior-rated anti-slip strips along the existing wooden wheelchair ramp.
- Evenly space and position strips along the ramp travel surface to improve traction.
- Ensure strips are securely attached and do not create a trip hazard.
- Product Example
Hallway/Kitchen Transition
Repair Flooring and Threshold
- Install Low-Profile Flooring Transition Strip
- Provide and install a low-profile transition strip to cover the existing gap between the linoleum and luxury vinyl plank (LVP) flooring at the hallway/kitchen transition.
- Ensure the transition strip is securely installed, lies flush against both flooring surfaces, and minimizes tripping hazards.
- Select a finish that matches the existing flooring as closely as possible.
Rear Entryway
Evaluate and Repair Rear Exterior Door
- Evaluate the existing rear exterior door, door frame, and locking hardware to determine the cause of difficulty opening and closing the door.
- Repair or adjust the door, frame, and locking hardware as necessary to ensure smooth operation.
- Replace damaged or malfunctioning components as needed.
- Ensure the door opens, closes, latches, and locks properly upon completion.
Exterior Doors
Install Wireless Door Alarms
- Provide and install wireless, battery-powered contact alarms on the three exterior doors only.
- Provide Batteries and securely install each alarm according to manufacturer instructions.
- Test all alarms following installation to confirm proper operation.
- Product Link
Contractors interested in submitting a bid may contact the disAbility Resource Center to obtain the project address and schedule a time to visit the site. Site visits are by appointment only and must be coordinated in advance. Inquiries may be emailed to sdavis@cildrc.org.
General Requirements
- Verify field conditions and exact quantities; request written approval for any substitutions.
- Where specific product links are provided in the Scope of Work, contractors must use the exact products referenced in those links unless a written substitution is approved bydRC prior to purchase.
- All grab bars/rails must support 350 lb+ when properly anchored; coordinate heights per OT input where available.
- Protect adjacent finishes; clean up daily; provide 1-year workmanship warranty.
- Work must comply with local building codes and aging-in-place best practices. For pre-1978 homes, EPA Lead-Safe Renovator certification and practices are required.
- Section 3 Compliance: This project is subject to the requirements of Section 3 of the Housing and Urban Development Act of 1968. Contractors and subcontractors are encouraged to make every effort to employ low-income persons and qualified Section 3 residents and to contract with Section 3 business concerns when feasible. Documentation of outreach and hiring efforts may be requested.
How to Apply / Submit a Bid
Due by the Closing Date:
• Completed bid/cost estimate with materials and labor itemized separately
• Proof of current Virginia contractor license
• Certificate of Insurance
• Lead-Safe and other certifications (if applicable)
• Completed W-9
Submit Bids or Questions to:
Samantha Davis, CAPS
Program Manager – Older Adult Home Modification Program
disAbility Resource Center
409 Progress St., Fredericksburg, VA 22401
540-373-2559 • sdavis@cildrc.org
Award Information
All bids will be reviewed for completeness, qualifications, and compliance with HUD requirements. The contract will be awarded to the bidder whose proposal is determined to be most advantageous to the project, considering price, experience, capacity, and overall responsiveness. Contractors may be contacted for clarification before an award decision is made. Award notifications will be posted and emailed within ten (10) business days of the closing date.
No comment yet, add your voice below!